A practical method for selecting 0.5-2.0 mm HDPE liner thickness from head, subgrade, service life and construction traffic.
By the Hengyang technical team · Published 2026-11-21 · Reviewed against GB/T standards and batch test practice
A common preliminary rule is t (mm) ≥ 0.5 + H (m)/100, where H is the design water head. A 10 m head therefore suggests about 0.6 mm as a starting point, before durability and construction allowances are added.
Sharp aggregate, rock fragments and construction plant increase puncture demand. For landfill base liners, 1.5 mm is standard; for hazardous waste 2.0 mm is common. Reservoirs typically use 1.0-1.5 mm, and small fish ponds 0.5-1.0 mm.
Thickness alone does not define performance. Check density, tensile yield, puncture resistance and carbon black content in the test report. Virgin resin liners resist stress cracking far better than recycled blends. The liner is part of a system: clay, GCL, geotextile, drainage and anchor details all interact. Use the calculated thickness as a check, not as a substitute for the design drawing.
Basis and limits. This note is based on GB/T 17643-2011, GB/T 17642-2008, GB/T 17638-2017 and GB/T 18173.1, together with Hengyang batch test practice. It is general technical guidance, not a design for a specific project. Confirm thickness, layer build-up, welding parameters and acceptance criteria against the project drawing and specification.
Send the drawing and design head. We will check the proposed thickness, cushion and weld detail against the specification.
Ask an engineerDrawings, head, area and chemical exposure are enough for a first selection. We reply within one working day.