A comparison for landfill caps, ponds and underground works, including hydration, space and protection requirements.
By the Hengyang technical team · Published 2026-11-21 · Reviewed against GB/T standards and batch test practice
A sodium bentonite blanket self-heals small punctures and needs no welding. It is thin, fast to install and well suited to landfill caps, vertical walls and soil-covered bases.
A composite geomembrane combines a membrane with geotextile, giving strong seepage control plus filtration and protection. It is common for canals, reservoirs and ponds where the liner is exposed to construction traffic.
GCL must hydrate to seal. In dry or wet-cycle conditions, or where the bentonite can migrate, a film-faced GCL or a composite membrane may be more reliable. Both systems need cover or protection. Exposed GCL can be eroded; exposed membrane ages under UV. The cover is part of the waterproofing system, not an optional extra.
Basis and limits. This note is based on GB/T 17643-2011, GB/T 17642-2008, GB/T 17638-2017 and GB/T 18173.1, together with Hengyang batch test practice. It is general technical guidance, not a design for a specific project. Confirm thickness, layer build-up, welding parameters and acceptance criteria against the project drawing and specification.
Send the drawing and design head. We will check the proposed thickness, cushion and weld detail against the specification.
Ask an engineerDrawings, head, area and chemical exposure are enough for a first selection. We reply within one working day.